Instrument pin description
CNA connector: Molex Minifit 6 pins
A1 -BATT Power supply negative reference
A2 -BATT Power supply negative reference
A3 CAN H Can signal high
A4 CAN L Can signal low
A5 HEATER+ Heater positive power supply. This input must be
connected to +BATT before the key switch.
A6 KEY Key input
CNB connector: Molex Minifit 4 pins
B1 NAUX Auxiliary load output. The external load is driven to –
Batt.
B2 PAUX Auxiliary load positive supply. This output is internally
connected to the key through a diode (cathode
connected to CNB#2)
B3 CANT Internally connected to CNA#4 through a Can-Bus 120
Ohm termination resistance. Connecting CNB#3 to
CNA#3 the termination resistance is inserted between
CAN L and CAN H.
B4 +BATT Power supply positive reference. This input must be
connected to +BATT before the key switch. CNB#4
supplies Graphic Smart Display also after the Key is
switched OFF for a programmable service time.
CNC connector: Molex Minifit 12 pins
C1 FLASH BOOT This input is used for the software download through
the microcontroller Asynchronous Serial Interface. To
connect the input to CNC#6 during this operation
otherwise leave it open.
C2 NCLRXD Serial reception negative
C3 PCLTXD Serial transmission positive
C4 NCLTXD Serial transmission negative
C5 GND Console negative power supply
C6 +12 Console positive power supply
C7 AN/DI 1 Analogue/digital input #1
C8 AN/DI 2 Analogue/digital input #2
C9 AN/DI 3 Analogue/digital input #3
C10 AN/DI 4 Analogue/digital input #4
C11 NPOT Power supply negative reference. It is used as potentiometer negative.
C12 PAN-IN Potentiometer positive: 12 V / 5 V output; keep load > 1kW / 0,5 KW
Number associated in canbus net MODULE
01 —— SICOS
02——-TRACTION
03——- TRACTION MASTER
04——-TRACTION SLAVE
05——- PUMP
06——- EPS-AC
09——– MHYRIO/HVC